Asian Journal of Transfusion Science
Home About Journal Editorial Board Search Current Issue Ahead of print Back Issues Instructions Subscribe Login  Users: 560 Print this page  Email this page Small font sizeDefault font sizeIncrease font size 


 
EDITORIAL Table of Contents   
Year : 2012  |  Volume : 6  |  Issue : 2  |  Page : 137-138
Hemovigilance and blood safety


1 Department of Transfusion Medicine, PGIMER, Chandigarh, India
2 Department of Transfusion Medicine, GMCH, Chandigarh, India

Click here for correspondence address and email

Date of Web Publication24-Jul-2012
 

How to cite this article:
Jain A, Kaur R. Hemovigilance and blood safety. Asian J Transfus Sci 2012;6:137-8

How to cite this URL:
Jain A, Kaur R. Hemovigilance and blood safety. Asian J Transfus Sci [serial online] 2012 [cited 2019 Nov 22];6:137-8. Available from: http://www.ajts.org/text.asp?2012/6/2/137/98911


The term hemovigilance is derived from the Greek word 'hema' = blood and the Latin word 'vigilans' = watchful. Hemovigilance is defined as a set of surveillance procedures covering whole transfusion chain from the collection of blood and its components to the follow up of its recipients, intended to collect and access information on unexpected or undesirable effects resulting from the therapeutic use of labile blood products, and to prevent their occurrence and recurrence. [1] Thus, the ultimate goal of a hemovigilance system is to improve the safety of blood transfusion.


   Historical aspects Top


The pioneering work on hemovigilance started in France in 1994 with the setup of monitoring systems by Blood Transfusion Committees and establishing a national hemovigilance system. [2] Later, in 1995 with an objective to improve public confidence in safe blood supply, the European Council published a resolution. Soon the hemovigilance system became governed by legal authorities. [3],[4] Data from well established hemovigilance systems of various countries such as the United Kingdom (Serious Hazards of Transfusion [SHOT]), Canada (Transfusion Transmitted Injuries Surveillance System [TTISS]), Netherlands (Transfusion Reactions in Patients [TRIP]), Japan, Russia, Switzerland, and the United States of America has provided insight into various measures, which can improve blood safety.

At present, on global scale an International Hemovigilance Network (IHN) is functioning which evolved from European Hemovigilance Network (EHN-founded in 1998). The aim of IHN is to develop and maintain a joint structure relating to the safety of blood and blood components and of hemovigilance in blood transfusion and transfusion medicine throughout the world. The IHN in coordination with International Society of Blood Transfusion (ISBT) working party on hemovigilance proposed standard definition for hemovigilance system (2011). [5]

To further maximize the safety of donors and recipients, an international database-International survilliance of transfusion associated reactions and events (ISTARE) has been developed (http://www.ihn-org.com/haemovigilance-databases/istare-2/), where the hemovigilance data can be shared across the world. The main aim of ISTARE is to capture all adverse reactions and incidents (events) in recipients of blood and blood products that can certainly, probably, or possibly be imputed to blood transfusion. It also records adverse events in blood donors.


   Scope of Hemovigilance Top


Scope of different hemovigilance systems varies due to differences in spectrum of reporting, that is, reporting of adverse reaction versus adverse events, all versus serious adverse reactions only; only incidents in recipients or also in donors; all adverse events or only the serious adverse reactions in recipients. [1] Ideally, the hemovigilance system should cover processes throughout the entire transfusion chain, from blood donation, processing, and transfusion to patients for the monitoring, reporting, and investigation of adverse events and reactions and near misses related to blood transfusion. It should be well coordinated between the blood transfusion service, hospital clinical staff and transfusion laboratories, hospital transfusion committees, regulatory agency, and national health authorities.


   Recipient hemovigilance Top


The 'severity' of an adverse event is graded according to an internationally accepted scale. The imputability, that is, the likelihood be attributed to the blood component transfused is also significant. The ISBT has laid down criteria for 'severity' and 'imputability' of transfusion reactions. [6] The transfusion reactions in a recipient are generally subdivided as acute (within 24 hours) or delayed (after hours of transfusion) reaction.


   Hemovigilance related to blood donors Top


The donor hemovigilance should include reporting of unexpected adverse events in whole blood and component donors and the action taken as a result. These events may be adverse reactions or complications resulting from donation, selection, and management of donors, which may directly harm the donor or influence the quality of the product, thereby putting the recipient at risk. [6] A joint working group from the ISBT and EHN has proposed a classification and a set of definitions of complications related to blood donation. [6]

In this issue of Asian Journal of Transfusion Science, there are interesting manuscripts focusing on different aspects of hemovigilance. Jeongeun et al., in their paper on code development of national hemovigilance system, concluded that few major categories could be added to the blood transfusion safety stages. Through their study, they could suggest expansion strategies of hemovigilance systems for hospital blood banks. In yet another manuscript by Agnihotri et al., there is an analysis of adverse events and predisposing factors in whole blood donors. They also concluded that analysis of adverse events helps in identifying the blood donors at risk of donor reactions and adopting appropriate donor motivational strategies.

Among the Asian countries, a well established hemovigilance system is lacking and there is paucity of data on hemovigilance except for Japan, which has published report on adverse reaction and infectious diseases (http://www.jrc.or.jp/vcms_lf/haemovigilanceannualreport1993-2001.pdf). The goal of establishing hemovigilance system in India is already in place under the National Blood Policy. [7] National Blood Transfusion Council will take a lead in developing the program with assistance of Technical Resource Group and a monitoring committee.

In order to have a well organized hemovigilance system in developing countries like India, a comprehensive approach is required. A streamlined mechanism for data collection using standardized tools at hospital level and good coordination at the national level can bring up effective hemovigilance system in a country. A functional hospital transfusion committee can act as backbone for this by developing policies for transfusion practices, appropriate documentation, reporting and investigation of transfusion reaction. In addition the draft recommendation on hemovigilance system by World Health Organization (WHO) may help in developing an efficient system in developing countries (http://www.bloodtransfusion.it/articoli/47/en/Doi%200010.pdf). The data from a well functioning hemovigilance system can be used as quality indicator for monitoring the blood transfusion safety, and also contribute significantly to evidence-based transfusion medicine.

 
   References Top

1.De Vries RR, Faber JC, Strengers PF. Hemovigilance: An effective tool for improving transfusion practice. Vox Sang 2011;100:60-7.  Back to cited text no. 1
    
2.De Vries RR. Haemovigilance: Recent achievements and developments in the near future. ISBT Sci Ser 2009;4:60-2.  Back to cited text no. 2
    
3.Faber JC. The European Blood Directive: A new era of blood regulation has begun. Transfus Med 2004;14:257-73.  Back to cited text no. 3
[PUBMED]    
4.Watson R. EU tightens rules on blood safety. BMJ 2005;331:800.  Back to cited text no. 4
    
5.Proposed standard definitions for surveillance of non-infectious adverse transfusion rections [Internet]. International Haemovigilance Network; 2011. Available from: http://www.isbtweb.org/fileadmin/user_upload/WP_on_Haemovigilance/ISBT_definitions_final_2011_.pdf. [Last Accessed on 2012 Jun 25].   Back to cited text no. 5
    
6.Stainsby D, Faber JC, Jorgensen J. Overview of hemovigilance. In: Simon TL, Solheim BG, Straus RG, Snyder EL, Stowell CP, Petrides M, editors. Rossi's Principles of Transfusion Medicine. 4 th ed. West Sussex: Blackwell Publishing; 2009. p. 694.  Back to cited text no. 6
    
7.National Blood Policy. New Delhi: National AIDS Control Organisation, Ministry of Health and Family Welfare, government of India; 2003 June.  Back to cited text no. 7
    

Top
Correspondence Address:
Ashish Jain
Department of Transfusion Medicine, PGIMER, Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.98911

Rights and Permissions



This article has been cited by
1 The Incidence Rate of Acute Transfusion Reactions in Thalassemia Patients Referred to the Shiraz Thalassemia Centre, Shiraz, Iran, Before and After the Establishment of the Hemovigilance System
Leila Kasraian,Mohammad H. Karimi
Hemoglobin. 2015; 39(4): 274
[Pubmed] | [DOI]
2 Hemovigilance program - India
Bisht, A. and Singh, S. and Marwaha, N.
Asian Journal of Transfusion Science. 2013; 7(1): 73-74
[Pubmed]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


   Historical aspects
    Scope of Hemovig...
    Recipient hemovi...
    Hemovigilance re...
    References

 Article Access Statistics
    Viewed2867    
    Printed242    
    Emailed4    
    PDF Downloaded15    
    Comments [Add]    
    Cited by others 2    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006