Turbid plasma donations: Need for quantification


Department of Transfusion Medicine, Fortis Hospital, Shalimar Bagh, Delhi, India

Click here for correspondence address and email

Date of Web Publication24-Jul-2014
 

How to cite this article:
Agnihotri N, Kumar L. Turbid plasma donations: Need for quantification. Asian J Transfus Sci 2014;8:78-9

How to cite this URL:
Agnihotri N, Kumar L. Turbid plasma donations: Need for quantification. Asian J Transfus Sci [serial online] 2014 [cited 2017 Mar 29];8:78-9. Available from: http://www.ajts.org/text.asp?2014/8/2/78/137436



   Illustration Top


No objective guidelines exist regarding handling of turbid blood units in developing countries. Therefore, use or discard of such units is decided as per local protocols which are mostly subjective and vary over time. Some of such turbid units are removed by blood centers at the time of preparation when 'milky appearance' is very gross, while some are returned by treating doctor at the time of transfusion. Overall, the frequency of lipemic donations ranges between 0.31 and 0.35%, [1] although sporadic reports have highlighted that the frequency might be much higher, up to 13%. Nonetheless, a significant numbers of such blood and plasma units are thus discarded each year. [2]

We came across a highly turbid plasma unit, prepared from a whole blood donation by a 37-year-old first time male donor. Unit was segregated from routine processing as it did not pass the 'label should be visible' test used at our center [Figure 1]. Medical history of the donor was reviewed and found to be insignificant. Donor had a weight of 70 kg and a blood pressure of 129/90 mmHg before donation. Serum lipid profile on the donated sample showed a very high triglyceride level of 3,168 mg/dl; cholesterol 358 mg/dl, high density lipoprotein (HDL) 23 mg/dl, and very low density lipoprotein (VLDL) 634 mg/dl. Despite repeated calls donor did not return for further evaluation. As, triglyceride levels were higher than those recommended by the equipment manufacturer for infectious marker (IM) testing (Vitros ECi by Ortho Clinical Diagnostics Inc. USA; enhanced chemilumniscence technique with highest concentration of triglyceride as 3000 mg/ dl as acceptable), sample [Figure 2] as well as unit had to be discarded. Also, spot test available with our center (Tridot by J. Mitra and Co., Okhla, New Delhi, India), declared interference/cross reactivity with lipemic serum and thus were not used for IM testing.
Figure 1: Turbid plasma bag (left) compared to normal plasma unit with visible label

Click here to view
Figure 2: Turbid blood sample from same unit (left) compared to normal blood sample

Click here to view


As shown by Peffer et al., simply having a meal before donation [3] may yield such a turbid unit. On the other hand, highly unfavorable cardiovascular profile [4] and elevated lipid levels may be the cause of such units, requiring further counseling of the donor. Additionally, as highlighted by Vassallo and Stearns, false-negative results on such turbid samples [5] may compromise the blood transfusion safety. Effect on transfusion recipients of such turbid units has not yet been studied in detail and is a gray area with regards to transfusion safety. Bashir and colleagues recently showed that use of such turbid plasma may increase the hemolysis if used for resuspension of red cells for exchange transfusion in neonates. [6]

Thus, the blood donors, the blood center, as well as the transfusion recipient; all are impacted by such turbid donations. Therefore, there is an imminent need to have studies on large sample size with an objective of providing guidelines for blood centres for testing as well as use of these turbid donations for blood transfusion purpose.

 
   References Top

1.Lippi G, Franchini M. Lipaemic donations: Truth and consequences. Transfus Apher Sci 2012.  Back to cited text no. 1
    
2.Morish M, Ayob Y, Maim N, Salman H, Muhamad NA, Yusoff NM. Quality indicators for discarding blood in the National Blood Center, Kuala Lumpur. Asian J Transfus Sci 2012;6:19-23.  Back to cited text no. 2
[PUBMED]  Medknow Journal  
3.Peffer K, de Kort WL, Slot E, Doggen CJ. Turbid plasma donations in whole blood donors: Fat chance? Transfusion 2011;51:1179-87.  Back to cited text no. 3
    
4.Bedi R, Basu S, Kaur P, Chattopadhya A. Visual inspection of blood units, a necessary practice at blood centers. Transfusion 2005;45:459.  Back to cited text no. 4
    
5.Vassallo R, Stearns FM. Lipemic plasma: A renaissance. Transfusion 2011;51:1136-9.  Back to cited text no. 5
    
6.Bashir S, Wiltshire M, Cardigan R, Thomas S. Lipaemic plasma induces haemolysis in resuspended red cell concentrate. Vox Sang 2012;104:218-24  Back to cited text no. 6
    

Top
Correspondence Address:
Naveen Agnihotri
Department of Transfusion Medicine, Blood Bank, Fortis Hospital, A-Block Shalimar Bagh - 110 088, Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.137436

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


   Illustration
    References
    Article Figures

 Article Access Statistics
    Viewed2070    
    Printed89    
    Emailed0    
    PDF Downloaded11    
    Comments [Add]    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006