Unconjugated hyperbilirubinemia in a blood donor: Chance finding due to unusual plasma discoloration


1 Department of Transfusion Medicine, AIIMS, Rishikesh, Uttarakhand, India
2 Department of Transfusion Medicine, SGPGIMS, Lucknow, Uttar Pradesh, India

Click here for correspondence address and email

Date of Submission30-Mar-2017
Date of Acceptance18-Apr-2017
Date of Web Publication16-Feb-2018
 

How to cite this article:
Jain A, Khetan D. Unconjugated hyperbilirubinemia in a blood donor: Chance finding due to unusual plasma discoloration. Asian J Transfus Sci 2018;12:8-9

How to cite this URL:
Jain A, Khetan D. Unconjugated hyperbilirubinemia in a blood donor: Chance finding due to unusual plasma discoloration. Asian J Transfus Sci [serial online] 2018 [cited 2018 Nov 15];12:8-9. Available from: http://www.ajts.org/text.asp?2018/12/1/8/225691




In a blood bank, the quality control of plasma is done by various semiautomated and automated instruments. However, with increasing automation, the art of manual visual inspection is slowly getting lost. In this communication, we describe how visual inspection is still useful and provides important information.

We received a blood donation from a 29-year-old repeat voluntary male donor, donating first time at our center. He gave a history of jaundice 3 years back with no known cause of jaundice but presently healthy. His hemoglobin was 17.1 by Hemocue 301 analyzer. Since he met the criteria for blood donation,[1],[2],[3] we accepted the donor. At our center, visual inspection of components is a routine protocol. After donation, while preparation of components, the unusual yellow color in the segments and plasma bag was noted [Figure 1] as compared to another normal unit [Figure 2]. The donor was negative for viral markers. We quarantined all components and donor was called for further evaluation. Upon subsequent examination and investigation, the bilirubin was 5.01 mg/dl and direct bilirubin was 1.5 mg/dl, and rest of the investigations including complete blood count with peripheral smear, liver enzymes, serum lactate dehydrogenase, serum creatinine, and serum erythropoietin were within normal range. The donor was referred to the gastroenterologist to evaluate for the cause of unconjugated hyperbilirubinemia and was clinically diagnosed as Gilbert's syndrome.
Figure 1: Photograph of the plasma unit showing abnormal yellow color

Click here to view
Figure 2: Photograph of the plasma unit showing normal yellow color

Click here to view


The color of plasma is often a subject of debate. The green color of plasma is commonly mentioned in literature and its significance is often associated with birth control pills.[4] The abnormalities in colors were also mentioned in a study by Sood et al., in which the 0.23% donation showed discoloration and total bilirubin of all the 5 units with yellowish plasma ranged from 1.6 to 2.3 mg/dl.[5] This high bilirubin might be an indirect marker of a number of diseases in donors. The total bilirubin found in our case was 5.01 mg/dl and the donor was clinically diagnosed as Gilbert's syndrome for which he was unaware of. Thus, a simple visual inspection led to benefit the donor by identifying his disease. The color of plasma may be the first sign for further bilirubin testing. Therefore, we recommend that visual inspection of plasma should be done carefully and conscientiously and any donor with such types of abnormality should be investigated for his health benefit.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Saran RK. Transfusion Medicine Technical Manual. DGHS. 2nd ed. India: Ministry of Health and Family Welfare; 2003. p. 8-17.  Back to cited text no. 1
    
2.
Standards for Blood Bank and Blood Transfusion Services. 1st edition; Ministry of health and family welfare India, NACO; 2007. p. 19-22.  Back to cited text no. 2
    
3.
Accreditation Standards for Blood Bank/Blood Centres and Transfusion Services. 3rd edition: NABH; 2016. p. 63-8.  Back to cited text no. 3
    
4.
Gorlin JB, Engblom A, Janzen M. Transfusion medicine illustrated. Green plasma in female blood donors on estrogen-containing birth control pills. Transfusion 2013;53:2122.  Back to cited text no. 4
[PUBMED]    
5.
Sood T, Bedi RK, Mittal K. Discolored blood and blood components: A dilemma for transfusion specialists. Transfus Apher Sci 2014;50:255-9.  Back to cited text no. 5
[PUBMED]    

Top
Correspondence Address:
Ashish Jain
Department of Transfusion Medicine, AIIMS, Rishikesh, Uttarakhand
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ajts.AJTS_34_17

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


    References
    Article Figures

 Article Access Statistics
    Viewed1311    
    Printed116    
    Emailed0    
    PDF Downloaded10    
    Comments [Add]    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006