Incompatible crossmatch: First sign of a hemolytic transfusion reaction due to out-of-group platelet transfusion


1 Department of Transfusion Medicine, Tata Medical Center, Kolkata, West Bengal, India
2 Department of Clinical Hematology and Bone Marrow Transplant, Tata Medical Center, Kolkata, West Bengal, India
3 Department of Gynaecological Surgery, Tata Medical Center, Kolkata, West Bengal, India

Click here for correspondence address and email

Date of Submission22-Mar-2017
Date of Acceptance21-Dec-2017
Date of Web Publication13-Jun-2019
 

   Abstract 

Platelet (PLT) transfusion is undertaken in a variety of clinical settings with thrombocytopenia, with or without bleeding. Since PLTs are most often stored in donor plasma, group-specific PLT transfusions are preferred to out-of-group transfusions. PLTs adsorb ABO antigens over their surface from the plasma. In major ABO-incompatible PLT transfusions, anti-A/B from the patient plasma react with the ABO antigens on transfused PLTs and can potentially cause adverse reactions or PLT refractoriness. Transfusion of PLTs with major ABO incompatibility, though effective in preventing clinical bleeding, is associated with reduced posttransfusion PLT count increments. In minor incompatible PLT transfusion transfused, anti-A/B can cause hemolytic transfusion reaction (HTR) which is not always related to a high titer of anti-A/B in the donor. Although attempts are made to practice ABO identical PLT transfusion, most centers practice out-of-group random donor platelets (RDPs) as well as single-donor-platelets (SDP) transfusion. The limited PLT shelf life does not always permit ABO identical PLT transfusion. At our center, ABO-specific PLT transfusions are practiced where possible, and in case of minor ABO-incompatible transfusions, antibody titers are not done. Here, we report a case of HTR due to out-of-group SDP transfusion, detected in the laboratory after an incompatible red blood cell (RBC) crossmatch.

Keywords: Hemolytic transfusion reaction, out-of-group SDP, platelet transfusion

How to cite this article:
Basu D, Basu S, Roy J, Reddy M, Chandy M, Bhaumik J. Incompatible crossmatch: First sign of a hemolytic transfusion reaction due to out-of-group platelet transfusion. Asian J Transfus Sci 2019;13:57-9

How to cite this URL:
Basu D, Basu S, Roy J, Reddy M, Chandy M, Bhaumik J. Incompatible crossmatch: First sign of a hemolytic transfusion reaction due to out-of-group platelet transfusion. Asian J Transfus Sci [serial online] 2019 [cited 2019 Sep 19];13:57-9. Available from: http://www.ajts.org/text.asp?2019/13/1/57/260309





   Introduction Top


D epending on the clinical condition of the patient, platelet transfusion can be therapeutic or prophylactic. In routine transfusion practice, out-of-group platelet transfusions are not uncommon due to the limited shelf life of platelets. Non-group specific PLT transfusion can lead to PLT refractoriness or HTR.[1] We report here a case of HTR following out-of-group SDP transfusion, detected retrospectively consequent to an incompatible RBC crossmatch.


   Case Report Top


A 56-year-old female, a case of carcinoma ovary Stage III C, received chemotherapy treatment of taxane plus carboplatin six cycles. Over 4 years, she had three relapses for which she received cisplatin, gemcitabine, avastin, and abraxane. Subsequently, she developed anemia requiring blood transfusion and thrombocytopenia and carboplatin was stopped. Bone marrow examination revealed hypocellular marrow without evidence of any malignancy. She was started on eltrombopag 50 mg OD, prednisolone 5 mg OD and erythropoietin 40,000/week, granulocyte colony-stimulating factor 300 μg weekly. After 1 month, peripheral blood smear showed 10% circulating blasts. Bone marrow aspiration showed 15% blasts, increased monocytes, and dysmyelopoiesis. Bone marrow biopsy revealed an increase in CD34+ immature precursors with increased monocytic component and dysmegakaryopoiesis consistent with myeloid neoplasm. Immunophenotyping results were suggestive of myelodysplastic syndrome (therapy related). She started receiving decitabine and was on transfusion support. The patient received several RBC transfusions (group-specific and crossmatch compatible) and many PLT transfusions, both RDPs and SDPs. PLT transfusions were not always group-specific as it depended on the RDP inventory and availability of group-specific SDP donors.

In this setting, we received a request for two RBC units for this patient. Now, crossmatch with four RBCs was all incompatible. Blood group, antibody screen (Surgiscreen cells, Resolve panel A), and anti-human globulin (AHG) crossmatch (poly-specific card) were done by column agglutination technique (Ortho Biovue Microbead System). Additional tests – heat elution, acid elution (BAG – elution kit, Ab Acid elution, Bag healthcare, Germany) and antibody titration (master dilution method-in tube technique) – were also done. The titration in AHG phase was done using DTT-treated plasma. Standard validated techniques were used. The patient's blood group was found to be A positive both in forward and reverse. As there was no blood group discrepancy, there was no irregular IgM antibody in the patient. Reaction with Anti-A1 lectin was 4+. The antibody screen was negative but crossmatch with four A-positive RBC units were all incompatible. The auto-control and direct antiglobulin test (DAT) (IgG only) were positive, both 3+. The family and medical history of the patient did not suggest any hereditary cause for the hemolysis. The positive DAT test indicated that some acquired immune phenomenon was going on in the patient's body. As DAT showed IgG antibodies and antibody screen was negative, acid elution was done. The eluate did not show any agglutination with panel screen cells. As antibody screening as well as elution results was negative, we concluded that the incompatibility was due to an antibody which was absent in the panel cells. Crossmatch of the eluate with A group RBC was incompatible, implying that the incompatibility was due to anti-A antibody. Heat elution was also done and antibody screen with eluate was negative, and crossmatch with A group RBC was compatible. Heat eluate showed negative reaction with A, B, and O cells at room temperature. As the acid eluate reacted with A cells and not with O cells, it is unlikely to be a case of drug-induced hemolysis because in that case, the eluate would be nonreactive with any drug nontreated cells and in the absence of the drug. Transfusion history revealed that in the last 48 h, she had received 4 RDP (two A positive and two O positive) and 2 SDP units (both O positive). Hence, it can be concluded that DAT and auto control were positive as a result of sensitization of the patient's red cells with passively transmitted anti-A (present in RDP and SDP) from donors. And also the incompatibility in crossmatch was caused by this passively transmitted anti A. Both SDP donors were called and fresh blood samples were obtained for anti-A isoagglutinin titration. The anti-A titers were 64 in saline, 512 in AHG in one donor; and 128 in saline, 1024 in AHG in the second donor. Retrospectively, we noted that following the SDP transfusions, hemoglobin dropped from 8.3 to 7.5 g/dl and unconjugated bilirubin increased from 0.8 to 2.2 mg/dl, indicating a hemolytic transfusion reaction. As one O-positive RBC unit was compatible with the patient's plasma, it was transfused and hemoglobin increased from 7.1 to 8.2 g/dl.


   Discussion Top


Hemolysis due to out-of-group SDP transfusions may be mild, delayed in presentation and thus go clinically unrecognized. Contributing factors include small blood volume recipient, exposures to large volumes of incompatible plasma and donors with high-titer anti-A and anti-B.[2] Reports have also shown that ABO antibody titers are not predictive of hemolytic reactions due to plasma incompatible PLT transfusions.[3] In the index case, an unrecognized hemolytic transfusion reaction occurred due to out-of-group PLT transfusion. The SDP donor had high anti-A antibody titer and neither was antibody titer estimated nor was any product modification done pretransfusion. Heat elution technique is routinely used for the elution of ABO antibody. In this case, as IgG was causing a positive DAT, we did acid elution. Subsequently, antibody identified was anti-A. Greco et al. reported that acid elution can also be used for ABO antibodies.[4] As antibody titers are not always predictive of hemolysis, anti-A/B titer estimation routinely in all minor incompatible PLT transfusions (RDP and SDP) is not cost-effective and judicious.[1] However, as the “dangerous O group” donors have high titer antibodies, O group SDP donors may be screened for high titers before minor incompatible SDP transfusion. Henceforth, we undertake O-group SDP procedures only if the donor antibody titers are <64. Other preventive measures such as plasma volume reduction and use of PLT additive solution for PLT storage can also be undertaken in minor incompatible SDP transfusion to reduce the chance of hemolysis. This communication also highlights the fact that out-of-group PLT transfusions must be kept in mind when investigating an incompatible crossmatch in a multi-transfused setting.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Valsami S, Dimitroulis D, Gialeraki A, Chimonidou M, Politou M. Current trends in platelet transfusions practice: The role of ABO-RhD and human leukocyte antigen incompatibility. Asian J Transfus Sci 2015;9:117-23.  Back to cited text no. 1
[PUBMED]  [Full text]  
2.
Quillen K, Sheldon SL, Daniel-Johnson JA, Lee-Stroka AH, Flegel WA. A practical strategy to reduce the risk of passive hemolysis by screening plateletpheresis donors for high-titer ABO antibodies. Transfusion 2011;51:92-6.  Back to cited text no. 2
    
3.
Karafin MS, Blagg L, Tobian AA, King KE, Ness PM, Savage WJ, et al. ABO antibody titers are not predictive of hemolytic reactions due to plasma-incompatible platelet transfusions. Transfusion 2012;52:2087-93.  Back to cited text no. 3
    
4.
Greco VA, Byrne KM, Procter JL, Stroncek DF. Detection of antibodies in acid eluates with the gel microcolumn assay. Transfusion 2002;42:698-701.  Back to cited text no. 4
    

Top
Correspondence Address:
Debapriya Basu
C/O Dr. Saumitra Kumar, 12, Santinagar Road, Bhadrakali, Hooghly - 712 232, West Bengal
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ajts.AJTS_36_17

Rights and Permissions




 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Case Report
   Discussion
    References

 Article Access Statistics
    Viewed265    
    Printed20    
    Emailed0    
    PDF Downloaded0    
    Comments [Add]    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006