Asian Journal of Transfusion Science
Home About Journal Editorial Board Search Current Issue Ahead of print Back Issues Instructions Subscribe Login  Users: 798 Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 13  |  Issue : 2  |  Page : 115-119

Comparison of a column agglutination technology-based automated immunohematology analyzer and a semiautomated system in pretransfusion testing


1 Department of Transfusion Medicine, Manipal Hospital, Jaipur, Rajasthan, India
2 Department of Transfusion Medicine, Medanta-The Medicity, Gurgaon, Haryana, India

Correspondence Address:
Aseem Kumar Tiwari
Department of Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon - 122 001, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ajts.AJTS_116_17

Rights and Permissions

INTRODUCTION: Semi-automated equipment using Column agglutination technology (CAT) is widely used where centrifugation and incubation are automated but substantial amount of the work is still executed manually. Larger laboratories are moving towards automation to eliminate errors, reducing exposure to bio-hazardous samples, assuring traceability, reliability, turnaround time (TAT) and throughput. Moving towards automation and greater reliability, we therefore, decided to install an automated immunohematological (IH) analyzer “Vision”. In this study we evaluated reliability and performance before clearing “Vision” for routine use. MATERIALS AND METHODS: Study was conducted in the Department of Transfusion-Medicine. The primary objective was to assess the reliability of results and compare with routine use semi-automated BIOVUE system (Reference system). Secondary objective was to evaluate the performance (TAT and throughput) of the Vision to handle routine and emergency workload. RESULTS: Total of 1276 known samples were used to assess 2640 pre-transfusion tests (1229 ABO/Rh D typing; 1229 antibody screening; 54 antibody identification; 86 crossmatch and 42 DAT). All 1229 ABO Rh typing results were concordant between the two systems. Overall agreement between the Vision IH analyzer and reference system for ABO Rh typing was 99.95%. All antibody screening, crossmatch and DAT results were concordant between the two systems. TAT of Vision was substantially shorter than the reference system for all test profiles. CONCLUSION: Based on study results, Vision was approved for routine use in laboratory. It was found to be reliable with considerably shorter TAT and capable of handling high throughput of immunohematological tests.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed254    
    Printed14    
    Emailed0    
    PDF Downloaded0    
    Comments [Add]    

Recommend this journal

 

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006