Asian Journal of Transfusion Science

ORIGINAL ARTICLE
Year
: 2009  |  Volume : 3  |  Issue : 2  |  Page : 86--94

Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods


Ravindra P Singh1, Neelam Marwaha1, Pankaj Malhotra2, Sumitra Dash3 
1 Deputy of Research, Kurdistan University of Medical Sciences, Iran
2 Sanandaj District Health Center, Kurdistan University of Medical Sciences, Iran
3 Kurdistan Organization of Blood Transfusion, Research Center, Iran

Correspondence Address:
Ravindra P Singh
Department of Transfusion Medicine, The Mission Hospital, Imon Kalyan Sarani, Sector 2C, Bidhan Nagar -713 216 (WB)
Iran

Background: Platelet rich plasma-platelet concentrate (PRP-PC), buffy coat poor-platelet concentrate (BC-PC), and apheresis-PC were prepared and their quality parameters were assessed. Study Design: In this study, the following platelet products were prepared: from random donor platelets (i) platelet rich plasma - platelet concentrate (PRP-PC), and (ii) buffy coat poor- platelet concentrate (BC-PC) and (iii) single donor platelets (apheresis-PC) by different methods. Their quality was assessed using the following parameters: swirling, volume of the platelet concentrate, platelet count, WBC count and pH. Results: A total of 146 platelet concentrates (64 of PRP-PC, 62 of BC-PC and 20 of apheresis-PC) were enrolled in this study. The mean volume of PRP-PC, BC-PC and apheresis-PC was 62.30±22.68 ml, 68.81±22.95 ml and 214.05±9.91 ml and ranged from 22-135 ml, 32-133 ml and 200-251 ml respectively. The mean platelet count of PRP-PC, BC-PC and apheresis-PC was 7.6±2.97 x 1010/unit, 7.3±2.98 x 1010/unit and 4.13±1.32 x 1011/unit and ranged from 3.2-16.2 x 1010/unit, 0.6-16.4 x 1010/unit and 1.22-8.9 x 1011/unit respectively. The mean WBC count in PRP-PC (n = 10), BC-PC (n = 10) and apheresis-PC (n = 6) units was 4.05±0.48 x 107/unit, 2.08±0.39 x 107/unit and 4.8±0.8 x 106/unit and ranged from 3.4 -4.77 x 107/unit, 1.6-2.7 x 107/unit and 3.2 - 5.2 x 106/unit respectively. A total of 26 units were analyzed for pH changes. Out of these units, 10 each were PRP-PC and BC-PC and 6 units were apheresis-PC. Their mean pH was 6.7±0.26 (mean±SD) and ranged from 6.5 - 7.0 and no difference was observed among all three types of platelet concentrate. Conclusion: PRP-PC and BC-PC units were comparable in terms of swirling, platelet count per unit and pH. As expected, we found WBC contamination to be less in BC-PC than PRP-PC units. Variation in volume was more in BC-PC than PRP-PC units and this suggests that further standardization is required for preparation of BC-PC. As compared to the above two platelet concentrates, all the units of apheresis-PC fulfilled the desired quality control criteria of volume. Apheresis-PC units showed better swirling and platelet count than PRP-PCs and BC-PCs. All the platelet concentrates units had pH well above the recommended norm.


How to cite this article:
Singh RP, Marwaha N, Malhotra P, Dash S. Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods.Asian J Transfus Sci 2009;3:86-94


How to cite this URL:
Singh RP, Marwaha N, Malhotra P, Dash S. Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods. Asian J Transfus Sci [serial online] 2009 [cited 2019 Jul 24 ];3:86-94
Available from: http://www.ajts.org/article.asp?issn=0973-6247;year=2009;volume=3;issue=2;spage=86;epage=94;aulast=Singh;type=0