   Abstract 

Introduction : Storage of red cells causes a progressive increase in hemolysis. In spite of the use of additive solutions for storage and filters for leucoreduction, some amount of hemolysis is still inevitable. The extent of hemolysis, however, should not exceed the permissible threshold for hemolysis even on the 42 nd day of storage. Study Design and Methods: Eighty units of packed red cells, 40 stored in SAGM post leucoreduction and 40 in ADSOL without leucoreduction filters, were evaluated for plasma hemoglobin by HemoCue Plasma Hemoglobin analyzer on the day of collection and on the 7 th , 14 th , 21 st , 28 th , 35 th and 42 nd days thereafter. The hemoglobin and hematocrit were also noted for all these units by the Beckman and Coulter analyzer. Percentage hemolysis was then calculated. Observations: Hemolysis progressively increased with the storage period in all the stored red cell units (SAGM as well ADSOL). However, on day 42 nd of storage, free hemoglobin in all the red cell units was within the permissible level (which is 0.8% according to the Council of Europe guidelines and 1% as per the US FDA guidelines). The mean percentage hemolysis was slightly higher in the SAGM-containing bags with an integral leucoreduction filter as compared to the bags containing ADSOL. However this difference was marginal and not statistically significant. Conclusion: Hemolysis of the red cells increases with storage. However, maximum hemolysis does not exceed the permissible limits at any time thereby indicating the effect of optimum processing and storage conditions on red cell hemolysis.

Keywords: Additive solutions, hematocrit, hemolysis, leucoreduction

How to cite this article:
Makroo R N, Raina V, Bhatia A, Gupta R, Majid A, Thakur UK, Rosamma N L. Evaluation of the red cell hemolysis in packed red cells during processing and storage. Asian J Transfus Sci 2011;5:15-7

How to cite this URL:
Makroo R N, Raina V, Bhatia A, Gupta R, Majid A, Thakur UK, Rosamma N L. Evaluation of the red cell hemolysis in packed red cells during processing and storage. Asian J Transfus Sci [serial online] 2011 [cited 2023 Mar 26];5:15-7. Available from: https://www.ajts.org/text.asp?2011/5/1/15/75970



   Introduction Top


There is yet no substitute for human blood and its components. In recent years, the need for stricter control over the quality of blood and its products has been emphasized. One such quality indicator for stored red cell units is the extent of hemolysis.

Hemolysis represents the breakdown or disruption of the integrity of the red blood cell membranes causing the release of hemoglobin. Hemolysis of red cell units occurs during preparation of components as well as during storage, issue, and transport to the patient. Hemolysis in blood products is usually manifested by the presence of free hemoglobin in the red cell suspending media, such as plasma or additive solutions. Storage of red cells causes a progressive increase in hemolysis. The extent of hemolysis can be estimated by various techniques, visual assessment being the most common. Others include spectrophotometric assays, photometric method, and microplate technique. [1],[2],[3],[4]

In spite of the increasing use of additive solutions for storage of red cells, some amount of hemolysis is inevitable. The extent of hemolysis, to some extent, varies with the composition of the additive solution used. ADSOL contains 50% more adenine and 150% more glucose in addition to 750 mg/dl of mannitol than does SAGM. The presence of leukocytes in the red cell units contributes significantly to an increase in red cell hemolysis during storage. [5],[6],[7] This is due to the release of various chemicals and enzymes, especially proteases from the leukocytes. For the same reason, various leukocyte reduction filters are commercially available. The presence of mannitol in the ADSOL medium reduces hemolysis even in the presence of leukocyte proteases. The percentage hemolysis progressively increases with the day of storage, irrespective of which additive solution has been used and whether or not the units are leucoreduced. However, even on day 42 nd of storage, free hemoglobin in any of the red cell units should not exceed the permissible level which is 0.8%, as per the Council of Europe guidelines [8] and 1% as per the US FDA guidelines. [9]


   Aims Top


The aim of the study was to evaluate the extent of RBC hemolysis with storage and the effect of leucoreduction and composition of the additive solution on the same.


   Materials and Methods Top


The present study on red cell hemolysis in packed red cells during processing and storage was conducted at the Department of Transfusion Medicine, Indraprastha Apollo Hospitals, New Delhi, between May and October 2009.

A total of 80 whole blood units were collected in CPD anticoagulant. After a holding period of at least 30 minutes, the components were separated from these blood units. Forty of the PRC units were stored in blood bags containing SAGM following 3 to 4 log leucoreduction via integral filters and 40 units were stored in ADSOL-containing bags, without integral filters giving only 1 log leucoreduction. All the packed red cell units were evaluated for plasma hemoglobin by HemoCue plasma hemoglobin analyzer. The first sample was collected immediately after processing, which was considered as the "Day 0" sample. Subsequently, all red cell units were stored under standard storage conditions at 2-6 o C. Further evaluation was done on 7 th , 14 th , 21 st , 28 th , 35 th , and 42 nd days of collection. The hemoglobin and hematocrit were also noted for all units each time by the Beckman and Coulter analyzer.

Each time 10 ml of the sample was collected aseptically from the units and centrifuged at 2000 rpm for 10 minutes. A large drop of the supernatant was pipetted out on the slide and the plasma/low Hb cuvette was filled from the drop. This was then inserted into the Hemocue photometer and the results were recorded. The percentage hemolysis was calculated by measuring the total Hb content, hematocrit, and supernatant Hb content of the PRC units using the following formula:



where Hb- hemoglobin; Hct- hematocrit; B-Hb- blood hemoglobin.

The data collected from the study were tabulated and then statistically evaluated to produce the following results.


   Results Top


In the PRC units stored in SAGM, the least hemolysis was observed on the day of collection (mean = 0.1%), and the maximum hemolysis was observed on the 42nd day of storage (mean = 0.553%). Similarly, in the PRC units that were stored in ADSOL, an increase in the percentage hemolysis was observed from a mean of 0.087% on day 0 to 0.538% on the 42nd day [Table 1] and [Table 2]. The maximum percentage hemolysis shown by any sample was 0.710% in SAGM and 0.697% in ADSOL. It was also noted that the mean percentage hemolysis on each evaluation was slightly higher in 3-4 log leoucoreduced PRC units stored in SAGM as compared to those stored in ADSOL [Figure 1]. However, the difference was not statistically significant. None of the samples showed percentage hemolysis of more than 0.8%, which is the maximum acceptable limit of hemolysis as per the Council of Europe Guidelines.
Table 1 :Hemolysis in SAGM-containing bags

Click here to view
Table 2 :Hemolysis in ADSOL-containing bags

Click here to view
Figure 1 :Comparison between SAGM and ADSOL

Click here to view



   Discussion Top


RBC units are prepared predominantly as concentrates (packed red cells) resuspended in additive solutions (SAGM/ADSOL) at our center. This prospective study was taken up to evaluate the extent of hemolysis during storage of packed red cells using two different additive solutions, and the effect of leucoreduction on the same. It was observed that the percentage hemolysis progressively increases from day 0 to day 42 of storage both in bags containing ADSOL (0.087-0.538) as well as SAGM (0.1-0.553) as additive solutions. It was also noted that the units that contained ADSOL as an additive solution showed slightly lower levels of hemolysis (maximum hemolysis being 0.697%) with respect to those containing SAGM (maximum hemolysis being 0.710%), even though the later were provided with integral leucoreduction filters. However, none of the units showed hemolysis more than the permissible limits, even on the 42nd day. At our center, we strictly follow the standard processing and storage guidelines. This could account for the satisfactory results obtained in our study.

Of the various methods that are available for the assessment of hemolysis, the visual method is the simplest; however the results are often inaccurate, misleading, and result in overestimation of hemolysis in red blood cells units. [2] In a study comparing spectrophotometric method and the photometric methods, Cardigan et al. demonstrated that both methods gave comparable results. [10] In our study we adopted the photometric method (HemoCue plasma hemoglobin analyzer) for the assessment of hemolysis.

Many authors in India as well as across the world have demonstrated that RBC hemolysis increases with the storage period of PRC. [11],[12] In one such study, Sawant et al. [11] evaluated plasma hemoglobin levels using the tetramethylbenzidiene (TMB) method on day 1, 7, 14, 21, and 28 of collection. The hemolysis in all the PRC units increased with the day of storage. These findings were in confirmation with those in our study. Besides this, they also observed that hemolysis in units that were stored in SAGM was higher compared to the units stored in ADSOL. In another study, Zimmerman et al. [1] also observed slightly higher level of hemolysis in SAGM-containing bags. They attributed this increase to the preparatory technique which they used (the PRP method). Other authors believe that this difference in the level of hemolysis between SAGM- and ADSOL-containing bags is due to the difference in composition of the two additive solutions. ADSOL contains 50% more adenine and 150% more glucose in addition to 750 mg/dl of mannitol than does SAGM. Mannitol acts as a membrane stabilizer and dextrose is required for the metabolism of stored red cells. [11] This could also account for the lower levels of hemolysis in ADSOL-containing bags in our study. It has also been described by various authors that the presence of leukocytes in the red cell units contribute significantly to an increase in red cell hemolysis during storage, [7],[10],[11] and that prestorage filtration helps in reducing the extent of this hemolysis. [13],[14] This is due to the release of various chemicals and enzymes, especially proteases from the leukocytes. For the same reason, various leukocytes reduction filters are commercially available. On the other hand, there have been a few reports in literature showing an increase in hemolysis with the use of leucoreduction filters. [15],[16]

In our study, the difference in the level of hemolysis was higher in SAGM bags (with leucoreduction filters) than in the corresponding ADSOL-containing bags, but did not reach significance.


   Conclusion Top


Hemolysis is a very important parameter for assessing the quality of stored RBCs. On assessing the effect of duration of storage on red cell hemolysis, we concluded that there is a progressive increase in the percentage hemolysis with storage, irrespective of the additive solution used. However, the extent of hemolysis does not exceed the recommended limits at any time during storage, thereby indicating efficacy of the processing and storage protocol followed at our center. Further, no significant difference was noted in the extent of hemolysis between 3 to 4 log leucoreduced PRC units stored in SAGM and 1 log leucoreduced PRC units stored in ADSOL.

 
   References Top

1.Zimmermann R, Heidenreich D, Weisbach V, Zingsem J, Neidhardt B, Eckstein R. In vitro quality control of red blood cell concentrates outdated in clinical practice. Transfus Clin Biol 2003;10:275-83.   Back to cited text no. 1
    
2.Janatpour KA, Paglieroni TG, Crocker VL, Dubois DJ, Holland PV. Visual assessment of hemolysis in red cell units and segments can be deceptive. Transfusion 2004;44:984-9.   Back to cited text no. 2
    
3.Cookson P, Sutherland J, Cardigan RA. Simple Spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates. Vox Sanguinis 2004;87:264-71.   Back to cited text no. 3
    
4.Seghatchian J, Krailadsiri P, Beard M, Vickers M. Development of a Microplate method for the measurement of plasma haemoglobin and its use in monitoring the storage lesion of red cell components. Transfus Apher Sci 2002;26:91-3.   Back to cited text no. 4
    
5.Greenwalt TJ, Zehner Sostock C, Dumaswala UJ. Studies in red blood cells preservation. Effect on the other formed elements. Vox Sang 1990;58:85-9.   Back to cited text no. 5
    
6.Humbert JR, Fermin CD, Winser EL. Early damage to granulocytes during storage. Semin Hematol 1991;28:10-3.   Back to cited text no. 6
    
7.Heaton WA, Holme S, Smith K, Brecher ME, Pineda A, AuBuchon JP, et al. Effects of 3-5 logs 10 prestorage leukocytes depletion on red cell storage and metabolism. Br J Hematol 1994;87:363-8.   Back to cited text no. 7
    
8.Guide to the preparation, use and quality assurance of blood components. 6th ed. Strasbourg Cedex Germany: Council of Europe Publishing; 2000.   Back to cited text no. 8
    
9.FDA summary basis of approval of red blood cells frozen and red blood cells deglycerolized (reference no. 86-0335). Applicant- Department of the Navy, Naval Hospital. Bethesda, MD, US License Number 1986. p. 635-10.   Back to cited text no. 9
    
10.Cardigan R, Smith K. Evaluation HemoCue plasma hemoglobin analyzer for assessing hemolysis in Red cell concentrates during storage. Vox Sanguinis 2002;82:76-9.   Back to cited text no. 10
    
11.Sawant RB, Jathar SK, Rajadhyaksha SB, Kadam PT. Red cell hemolysis during processing and storage. Asian J Transfus Sci 2007;1(2): 47-51.   Back to cited text no. 11
    
12.Sowemimo-Coker SO. Red blood cell hemolysis during processing. Transfus Med Rev 2002;16:46-60.   Back to cited text no. 12
    
13.Rogers SE, Edmondson D, Goodrick MJ, Standen GR, Franck V, Reppucci A, et al. Prestorage white cell reduction in saline-adenine-glucose-mannitol red cells by use of an integral filter: evaluation of storage values and in vivo recovery. Transfusion 1995;35:727-33.   Back to cited text no. 13
    
14.Heaton WA, Holme S, Smith K, Brecher ME, Pineda A, AuBuchon JP, et al. Effects of 3-5 log10 pre-storage leucocyte depletion on red cell storage and metabolism. Br J Hematol 1994;87:363-8.   Back to cited text no. 14
    
15.Gammon RR, Strayer SA, Avery NL, Mintz PD. Hemolysis during leukocyte-reduction filtration of stored red blood cells. Ann Clin Lab Sci 2000;30:195-9.   Back to cited text no. 15
    
16.Müller-Steinhardt M, Janetzko K, Kandler R, Flament J, Kirchner H, Klüter H. Impact of various red cell concentrate preparation methods on the efficiency of prestorage white cell filtration and on red cells during storage for 42 days. Transfusion 1997;37:1137-42.  Back to cited text no. 16
    

Top
Correspondence Address:
R N Makroo
Department of Transfusion Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, New Delhi 110 076
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.75970

Rights and Permissions


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2]

This article has been cited by
1 Red cells manufactured from lipaemic whole blood donations: Do they have higher haemolysis?
Kelly M. Winter, Rachel G. Webb, Denese C. Marks
Vox Sanguinis. 2022;
[Pubmed] | [DOI]
2 CHANGES IN BLOOD DURING STORAGE FOR TRANSFUSION
Athanasios V. Bakaloudis, Marianna G. Andreadou, Irini M. Kalogiannidou, Nazli O. Osman, Konstantinos S. Mavromatidis
PARIPEX INDIAN JOURNAL OF RESEARCH. 2022; : 118
[Pubmed] | [DOI]
3 A study to assess the relationship between donor uric acid levels and supernatant hemolysis in stored packed red blood cell units
HimanshuKumar Singh, AmitKumar Biswas, Joseph Philip, Neerja Kushwaha, Bhasker Mukherjee, AjayK Baranwal
Asian Journal of Transfusion Science. 2022; 16(2): 254
[Pubmed] | [DOI]
4 Quantitative assessment of infusion pump-mediated haemolysis in feline packed red blood cell transfusions
Carles Blasi-Brugué, Ignacio M Sanchez, Rui RF Ferreira, Augusto JF de Matos, Rafael Ruiz de Gopegui
Journal of Feline Medicine and Surgery. 2021; 23(12): 1149
[Pubmed] | [DOI]
5 Surface modified multifaceted nanocarriers for oral non-conventional cancer therapy; synthesis and evaluation
Fiza ur Rehman, Kehkashan Mazhar, Annum Malik, Syeda Sohaila Naz, Kifayat Ullah Shah, Adnan Khan, Salman Khan, Rizwan Ahmed, Sara Qaisar
Materials Science and Engineering: C. 2021; 123: 111940
[Pubmed] | [DOI]
6 Cytotoxic effect of cipó-pucá (Cissus sicyoides L.) supercritical extract on human red blood cells and as anti-inflammatory in spinal cord injury in adult rats
Marielba de los Ángeles Rodríguez Salazar, Glides Rafael Olivo Urbina, Vânia Maria Borges Cunha, Fernanda Wariss Figueiredo Bezerra, Michelle Nerissa Coelho Dias, Ijair Rogério Santos, Bruno José Brito Teixeira, Wanessa Almeida Costa, Walace Gomes-Leal, Jesus Nazareno Silva e Souza, Silvia Helena Marques Silva, Raul Nunes Carvalho Junior
The Journal of Supercritical Fluids. 2021; 169: 105105
[Pubmed] | [DOI]
7 Combined Platelet and Erythrocyte Salvage: Evaluation of a New Filtration-based Autotransfusion Device
Alexandre Mansour, Benoit Decouture, Mikaël Roussel, Charles Lefevre, Lucie Skreko, Véronique Picard, Alexandre Ouattara, Christilla Bachelot-Loza, Pascale Gaussem, Nicolas Nesseler, Isabelle Gouin-Thibault
Anesthesiology. 2021; 135(2): 246
[Pubmed] | [DOI]
8 In vitro and In vivo Biocompatibility Evaluation of Freeze Dried Gelatin Haemostat
S. Sneha Letha, Santosh Kumar Shukla, Neena Haridas, R. P. Smitha, M. Sidharth Mohan, V. Archana, M. J. Rosemary
Fibers and Polymers. 2021; 22(3): 621
[Pubmed] | [DOI]
9 The effect of position and frequency of mixing on canine packed red blood cell units during storage
Samantha M. Aumann, Miryam M. Reems
Journal of Veterinary Emergency and Critical Care. 2021;
[Pubmed] | [DOI]
10 Radiation fabrication of Xanthan-based wound dressing hydrogels embedded ZnO nanoparticles: In vitro evaluation
Amany I. Raafat, Naeem M. El-Sawy, Nagwa A. Badawy, Eglal A. Mousa, Asmaa M. Mohamed
International Journal of Biological Macromolecules. 2018; 118: 1892
[Pubmed] | [DOI]
11 Biochemical Storage Lesions Occurring in Nonirradiated and Irradiated Red Blood Cells: A Brief Review
F. Adams,G. Bellairs,A. R. Bird,O. O. Oguntibeju
BioMed Research International. 2015; 2015: 1
[Pubmed] | [DOI]
12 A hemolysis study of an intravascular blood cooling system for localized organ tissue cooling
Merrill, T.L. and Mingin, T. and Merrill, D.R. and Botbyl, J. and Akers, J.E.
Perfusion (United Kingdom). 2013; 28(1): 6-13
[Pubmed]
13 In vitro measures of membrane changes reveal differences between red blood cells stored in saline-adenine-glucose-mannitol and AS-1 additive solutions: a paired study
Rosemary L. Sparrow,Amrita Sran,Geraldine Healey,Margaret F. Veale,Philip J. Norris
Transfusion. 2013; : n/a
[Pubmed] | [DOI]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
    Introduction
    Aims
    Materials and Me...
    Results
    Discussion
    Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed7371    
    Printed461    
    Emailed3    
    PDF Downloaded167    
    Comments [Add]    
    Cited by others 13    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice


© 2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006