Asian Journal of Transfusion Science
Home About Journal Editorial Board Search Current Issue Ahead of print Back Issues Instructions Subscribe Login  Users: 525 Print this page  Email this page Small font sizeDefault font sizeIncrease font size 


 
ILUSTRATION Table of Contents   
Year : 2012  |  Volume : 6  |  Issue : 1  |  Page : 44-45
Nonspecific red cell aggregation interferes in the interpretation of gel test results


1 Department of Transfusion Medicine, Government Medical College and Hospital, Chandigarh, India
2 Department of Pathology, Government Medical College and Hospital, Chandigarh, India

Click here for correspondence address and email

Date of Web Publication16-Apr-2012
 

How to cite this article:
Basu S, Kaur R, Kaur G, Kaur P, Tahlan A. Nonspecific red cell aggregation interferes in the interpretation of gel test results. Asian J Transfus Sci 2012;6:44-5

How to cite this URL:
Basu S, Kaur R, Kaur G, Kaur P, Tahlan A. Nonspecific red cell aggregation interferes in the interpretation of gel test results. Asian J Transfus Sci [serial online] 2012 [cited 2022 Aug 11];6:44-5. Available from: https://www.ajts.org/text.asp?2012/6/1/44/95051



   Introduction Top


Samples with abnormal serum protein concentration, altered serum protein ratio, or high-molecular weight volume expanders are known to induce rouleaux formation which can mimic agglutination. Serum factors inducing rouleaux and spontaneous red cell aggregation interfere in the interpretation of routine serological tests.


   Observation Top


A 24-year-old lady with a provisional diagnosis of Immune hemolytic anemia, was referred to us for the direct and indirect antiglobulin test (DAT, IAT). The anticoagulated blood sample showed visible agglutinates along the sides of the test tube, and a wet preparation from the EDTA sample also showed similar findings [Figure 1]a. However, on addition of drops of normal saline onto the slide, the agglutination disappeared; thereby, raising the possibility of rouleaux formation.
Figure 1: (a) Wet preparation of EDTA blood sample. (b) Autocontrol

Click here to view


Clinical details of the patient revealed that she had intermittent high-grade fever for past 5-6 months with a moderate splenomegaly. The patient had severe anemia (Hb 50 g/l), a total leukocyte count of 4.6 × 10 9 /l with relative lymphocytosis, and platelets were just adequate. Bone marrow aspiration done showed a reactive marrow with excess of plasma cells (18%). A careful search revealed amastigote forms of Leishman donovani, both intracellular and extracellular forms, confirming a diagnosis of visceral leishmaniasis. Biochemistry tests revealed elevated total proteins (patient 78 g/l, normal 55-70 g/l) with reversal of albumin-globulin ratio (patient albumin 27 g/l, normal 35-55 g/l). With these findings, an impression of rouleaux formation due to altered albumin-globulin ratio was considered and an attempt to rule out any additional antibodies was made. An autocontrol was performed on the Diamed ID microtyping system. Results showed 2+ agglutination with 0.8% LISS suspended red cells, and 1+ agglutination with washed red cells in LISS. However, when warm saline washed red cells in LISS were used, the autocontrol was negative [Figure 1]b. The IAT and DAT were performed by the tube method. For the IAT, after routine incubation, saline replacement technique [1] was used and for the DAT, red cells were first washed thoroughly to remove serum factors. Both IAT and DAT were negative.


   Conclusion Top


Visceral leishmaniasis is common in coastal states of eastern India and it may be associated with hypergammaglobulinemia. [2] In all such cases, the possibility of a false positive auto control exists. Abnormal concentrations of serum proteins are also known to interfere with blood grouping, by inducing rouleaux formation and spontaneous red cell aggregation. [3] This can be eliminated by thoroughly washing the red cells and retesting. For detecting antibodies in the presence of rouleaux, saline replacement or saline dilution method is used. [1] These techniques are also used to resolve ABO discrepancies due to rouleaux formation. The report emphasizes that nonspecific red cell aggregation interferes with the interpretation of gel test results. It highlights the need for warm saline washing of red cells before making the LISS suspension for the gel technique, in cases of hypergammaglobulinemia. In addition, reviewing the serological findings in the light of clinical and other laboratory data often helps resolve discrepant test results.

 
   References Top

1.Issit PD, Anstee DJ. Applied blood group serology. 4 th ed. Durham, NC: Montgomery Scientific Publications; 1998. p. 1135.  Back to cited text no. 1
    
2.Dedet JP, Pratlong F. Leishmaniasis. In: Cook GC, Zumla AI, editors. Manson's Tropical Medicine. 22 nd ed. Philadelphia, PA: Saunders/Elsevier; 2009. p. 1364.  Back to cited text no. 2
    
3.Harmening DM, Firestone D. The ABO blood group system. In: Harmening DM, editor. Modern blood banking and transfusion practices. 5 th ed. Baltimore, Maryland: F. A. Davis Company; 2005. p. 108-32.  Back to cited text no. 3
    

Top
Correspondence Address:
Sabita Basu
Department of Transfusion Medicine, Government Medical College and Hospital, Chandigarh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.95051

Rights and Permissions


    Figures

  [Figure 1]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


   Introduction
   Observation
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed3303    
    Printed122    
    Emailed0    
    PDF Downloaded54    
    Comments [Add]    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice


2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006