Asian Journal of Transfusion Science
Home About Journal Editorial Board Search Current Issue Ahead of print Back Issues Instructions Subscribe Login  Users: 105 Print this page  Email this page Small font sizeDefault font sizeIncrease font size 


 
ORIGINAL ARTICLE Table of Contents   
Year : 2015  |  Volume : 9  |  Issue : 2  |  Page : 185-188
Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context


1 Department of Transfusion Medicine, Medanta-The Medicity, Gurgaon, Haryana, India
2 Department of Microbiology, Fortis Memorial Research Institute, Gurgaon, Haryana, India
3 Department of Microbiology, Medanta-The Medicity, Gurgaon, Haryana, India
4 Department of Gastroenterology, Medanta-The Medicity, Gurgaon, Haryana, India

Click here for correspondence address and email

Date of Web Publication12-Aug-2015
 

   Abstract 

Introduction: Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. Materials and Methods: The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS ® Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. Results: An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. Conclusion: The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.

Keywords: Anti-hepatitis C virus tests, Center for Disease Control, chemiluminescence immuno-assay, polymerase chain reaction, testing algorithm

How to cite this article:
Tiwari AK, Pandey PK, Negi A, Bagga R, Shanker A, Baveja U, Vimarsh R, Bhargava R, Dara RC, Rawat G. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context. Asian J Transfus Sci 2015;9:185-8

How to cite this URL:
Tiwari AK, Pandey PK, Negi A, Bagga R, Shanker A, Baveja U, Vimarsh R, Bhargava R, Dara RC, Rawat G. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context. Asian J Transfus Sci [serial online] 2015 [cited 2021 Mar 8];9:185-8. Available from: https://www.ajts.org/text.asp?2015/9/2/185/154259



   Introduction Top


Hepatitis C virus (HCV) is a major public health problem worldwide with around 3% of the world's population infected with HCV. [1] It is responsible for chronic liver disease, [2] may lead to cirrhosis and/or hepatocellular carcinoma and is a leading cause of liver transplantation. [3] Asymptomatic infection or nonspecific symptoms and varied clinical presentations make it difficult to diagnose this infection. Routine diagnosis of HCV infection is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). These anti-HCV tests are used widely for clinical diagnosis and screening of asymptomatic persons. Among populations with a low (<10%) prevalence of HCV infection, false-positive results do occur as these tests are very sensitive. [4],[5],[6],[7],[8],[9],[10],[11] These false positive results are there despite published reports exhibiting high specificity of commonly used test-kits. [12] Center for Disease Control (CDC), United States, has recommended that a person should be considered to have serologic evidence of HCV infection only after an anti-HCV screening-test-positive result has been confirmed by a reflex serologic test which is more specific like recombinant immunoblot assay (RIBA) or nucleic acid test (NAT). [13]

Center for Disease Control reported that the value of signal-to-cut-off (s/co) ratios in the anti-HCV antibody tests like EIA and CIA can be used to predict the probable result of the supplemental test-which means that above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. CDC guidelines of 2003 [14] indicate that for CIA (Ortho Clinical Diagnostics) this "certain s/co" value is eight (8). Test value above this specific s/co ratio of eight would predict a true antibody-positive result >95% of the time, regardless of the HCV prevalence or characteristics of the population being tested. Supplemental testing of screening-test-positive samples could then be limited to those with a low (<8) s/co ratio, while screening test-positive samples with high s/co ratio can be reported as anti-HCV antibody positive without reflex supplemental testing. Since there is no such study on an appropriate s/co ratio for anti-HCV antibody testing in India, a prospective study was undertaken in hospital patients in a tertiary care setting to ascertain similar s/co value and whether such value will work in our context.

The aim of this study was to determine s/co ratio for screening CIA testing kit routinely used in our lab that would predict a true antibody positive result 95% of the times in the patient population.


   Materials and Methods Top


Study settings and duration

The study was carried out in a multi-disciplinary tertiary care hospital from November 2012 to December 2012.

Study population

Patients of all ages requiring HCV testing for screening/diagnosis and medical management of their clinical condition were included in the study. Most of these were admitted patients who were evaluated according to the standard presurgical work-up, which includes tests for human immunodeficiency virus (HIV) 1 and 2, hepatitis B and hepatitis C.

Samples

Consecutive serum (clotted whole blood) samples from admitted presurgical patients tested for anti-HCV on CIA during the period of study were included for calculating and establishing a significant s/co value, which can be used as a predictor of positive HCV antibody status.

Screening test

The anti-HCV screening test used was enhanced CIA (VITROS ® Anti-HCV assay, Ortho-Clinical Diagnostics, Raritan, New Jersey). Specimens with a single reactive result are considered screening test-positive and do not require retesting (unlike EIA). Vitros EciQ Immunodiagnostic system is a fully automated, random and stat access immunodiagnostic analyzer, which works on the principle of enhanced chemiluminescence. The sensitivity and specificity of Vitros anti-HCV reported in the kit-insert is 100% and 99.75%, respectively.

Supplemental tests (nucleic acid test)

The supplemental NAT used was an Abbott real-time polymerase chain reaction (RT-PCR). The Abbott RT HCV assay uses RT-PCR 17 to generate amplified product from the RNA genome of HCV in clinical specimens. In addition, an RNA sequence that is unrelated to the HCV target sequence is introduced into each specimen at the beginning of sample preparation. This unrelated RNA sequence is simultaneously amplified by RT-PCR and serves as an internal control to demonstrate that the process has proceeded correctly for each sample. The amount of target sequence that is present at each amplification cycle is measured through the use of fluorescent labeled oligonucleotide probes on the Abbott m2000rt instrument. The probes do not generate a signal unless they are specifically bound to the amplified product. The amplification cycle at which the HCV-specific fluorescent signal is detected by the Abbott m2000rt is proportional to the log of the HCV RNA concentration present in the original sample.

Classification of test results

The gold standard for this study was this supplemental PCR test-result. Results of supplemental tests were considered final and true negatives, false negatives, true positives, and false positives were calculated accordingly. Samples negative with CIA and PCR were considered true negatives while samples with negative CIA and positive PCR were considered as false negatives. Samples that were positive by CIA and PCR were considered true positives while sample that was reactive by CIA but negative on PCR was considered false positive.

Data collection and analysis

All the data were stored in Microsoft excel sheets (Microsoft corporation, USA) and finally was analyzed using the the Statistical Package for the Social Sciences (SPSS), version 20.0 (SPSS Inc., Chicago, IL, USA . The performance of CIA versus the supplemental tests was measured using following statistical parameters: [15]

  • Sensitivity (Sn): True positive/true positive + false negative × 100
  • Specificity (Sp): True negative/true negative + false positive × 100
  • Positive predictive value (PPV): True positive/true positive + false positive × 100
  • Negative predictive value (NPV): True negative/true negative + false negative × 100.


To assess the efficacy of s/co threshold versus PCR, Sn and PPV of different putative s/co ratios were listed and calculated. The most appropriate s/co was considered on the basis of highest specificity at the sensitivity of at least 95%. Further, statistical analysis was performed to find receiver operator characteristics (ROC) of the s/co ratio and calculating the area-under-curve (AUC).

Ethical clearance

The study was approved by the Institutional Review Board and an independent Ethics Committee.


   Results Top


A total of 438 consecutive patient samples were tested with both CIA and PCR. As shown in [Table 1], 116 (true positives) out of 142 CIA positive samples were confirmed positives, while 26 CIA positive samples were not confirmed (false positives) with a supplemental test. 290 (true negatives) out of 296 samples were negative with both CIA and PCR, while 6 (false negatives) out of these 296 were missed by CIA. This gives the calculation of sensitivity as 95.1% and specificity of 91.8%. The predictive value of the positive test (PPV) was 81.7%, and the predictive value of negative test (NPV) was as high as 98%.
Table 1: Testing results of 438 consecutive patients tested with CIA and PCR


Click here to view


When the sensitivity and specificity values of various putative s/co values were calculated, the s/co value of both five (5) and six (6) had a sensitivity of over 95% and specificity of 91.7% as shown in [Table 2]. Over this cut-off value of six, the sensitivity started declining with specificity gaining ground at higher s/co ratios. Erring on the side of caution, six (6) seems to be the most appropriate s/co ratio to predict a true antibody-positive result >95% of the time, in the patient population. It also means that at a cut-off of higher than six the results can be released as positive without the need for doing supplementary test. This change in algorithm reduces the number of unnecessary supplemental tests.
Table 2: Sensitivity and specificity of various putative s/co ratios for deciding the appropriate cut-off


Click here to view


The diagnostic accuracy of this s/co ratio of six was also confirmed by plotting a ROC. The AUC of the ROC curve was 0.985 (95% confidence interval: 0.971-1.000) ([Figure 1]).
Figure 1: The receiver operator characteristics curve for signal-to-cut-off ratio of six (6)


Click here to view



   Discussion Top


The factors unique to HCV testing for detection of HCV infection are comparatively long window period of around 60 days, before antibodies are detectable and rapid multiplication of the virus with a doubling time of 0.45 days causing high viremia within a short period of few days. The combination of slow development of antibody marker and rapid viral replication results in high viral load and higher probability of HCV transmission as compared to other transfusion transmissible infections like HIV and hepatitis B virus, through blood component transfusion, sharing needles amongst intra-venous drug users and unsafe sexual practices. Moreover, the probability of false-positive result with the screening tests is higher with anti-HCV antibody detection. [4],[5],[6],[7],[8],[9],[10],[11] In Indian context also, it has been reported that the specificity of HCV antibody detection in serology tests is low. In this report nearly 45% of the screening assay reactive samples, tested negative by confirmatory tests (Immunoblot and Line Immuno-assay). [16] It is, therefore, not correct to label a patient as HCV positive on the basis of a single anti-HCV antibody detection test, irrespective of the kit/technique used. It can possibly be used in patients with known viral hepatitis for monitoring the response to treatment along with viral-load assay and estimation of liver enzymes. However, the screening test reactive result in asymptomatic cases like patients going for various surgeries, will have limited accuracy in predicting the true HCV infection status. It is, therefore, prudent to follow-up the initial anti-HCV screening tests with more specific supplemental assay like RIBA/NAT. Such confirmation of the presence of anti-HCV antibody by supplemental tests minimizes unnecessary medical visits and psychological harm for persons who test false positive by screening assays and ensures that counseling, medical referral, and evaluation are targeted for patients serologically confirmed as infected with HCV. [13]

In the armamentarium of supplemental assays - RIBA and NATs, RIBA is no longer available with world-wide shortages. Food and Drugs Administration (FDA), US has issued a guidance saying that "when current donor test-results are repeatedly reactive on an anti-HCV screening test and reactive on HCV NAT, the reactive NAT acts as a positive supplemental test and it is not necessary to perform a licensed multi-antigen supplemental test for anti-HCV." [17] This explains the use of PCR as the confirmatory supplemental tests in the present study. The latest Morbidity and Mortality report update on testing for HCV infection states that "Chiron RIBA HCV 3.0 Strip Immunoblot Assay (Novartis Vaccines and Diagnostics) that was recommended for supplemental testing of blood samples after initial HCV antibody testing is no longer available." It adds that "As a result, the only other FDA-approved supplemental tests for HCV infection are those that detect HCV viremia." [18]

The suggested use of elevated s/co ratio of eight (8) in the "Guidelines for Laboratory Testing and Result Reporting of Antibody to HCV" [14] is based on American Red-cross data where 64% of 24,700 Ortho anti-HCV EIA repeatedly reactive donations were RIBA positive, and of those, 94% of samples having an EIA s/co value of at least 4.0 tested RIBA positive. Similarly, the s/co ratio for CIA was computed at eight (8). The present study on CIA found the s/co ratio of six (6) to be the most appropriate. This s/co ratio of six is very similar to eight. These results are consistent with those of several previous studies. [19],[20],[21],[22],[23],[24],[25] According to Seo et al., the anti-HCV s/co ratio accurately predicts HCV viremia in patients positive for anti-HCV. Using anti-HCV EIA (Architect i2000; Abbott Laboratories, Abbott Park, IL, USA) in 487 patients anti-HCV s/co ratio cut-off value of 10.9 had high sensitivity and specificity of 94.4% and 97.3%, respectively. [26]

Moreover, the ROC-curve further substantiated six (6) as the appropriate s/co, since AUC of 0.95 was quite close to the ideal AUC of one (1) as illustrated in [Figure 1].

This allows for a newer algorithm of lab-diagnosis of HCV for patients. Those with an s/co higher than six can be said to have HCV infection. It goes without saying that a physician would see this in light of the clinical picture comprising of medical history, physical examination and other investigations such as liver enzymes, viral-loads, etc.


   Conclusion Top


The s/co ratio of six (6) can be used for diagnosing HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays. This changed algorithm would benefit the hospital and health-care settings to reduce the turn-around-time without compromising on the accuracy of lab-diagnosis of HCV in patients.

 
   References Top

1.
World Health Organization. Global surveillance and control of hepatitis C. Report of a WHO Consultation organized in collaboration with the Viral Hepatitis Prevention Board, Antwerp, Belgium. J Viral Hepat 1999;6:35-47.  Back to cited text no. 1
    
2.
Di Bisceglie AM. Hepatitis C. Lancet 1998;351:351-5.  Back to cited text no. 2
    
3.
Thomas DL, Astemborski J, Rai RM, Anania FA, Schaeffer M, Galai N, et al. The natural history of hepatitis C virus infection: host, viral, and environmental factors. JAMA 2000;284:450-6.  Back to cited text no. 3
    
4.
Kleinman S, Alter H, Busch M, Holland P, Tegtmeier G, Nelles M, et al. Increased detection of hepatitis C virus (HCV)-infected blood donors by a multiple-antigen HCV enzyme immunoassay. Transfusion 1992;32:805-13.  Back to cited text no. 4
    
5.
Conry-Cantilena C, VanRaden M, Gibble J, Melpolder J, Shakil AO, Viladomiu L, et al. Routes of infection, viremia, and liver disease in blood donors found to have hepatitis C virus infection. N Engl J Med 1996;334:1691-6.  Back to cited text no. 5
    
6.
Hyams KC, Riddle J, Rubertone M, Trump D, Alter MJ, Cruess DF, et al. Prevalence and incidence of hepatitis C virus infection in the US military: a seroepidemiologic survey of 21,000 troops. Am J Epidemiol 2001;153:764-70.  Back to cited text no. 6
    
7.
Alter MJ, Kruszon-Moran D, Nainan OV, McQuillan GM, Gao F, Moyer LA, et al. The prevalence of hepatitis C virus infection in the United States, 1988 through 1994. N Engl J Med 1999;341:556-62.  Back to cited text no. 7
    
8.
Montecalvo MA, Lee MS, DePalma H, Wynn PS, Lowenfels AB, Jorde U, et al. Seroprevalence of human immunodeficiency virus-1, hepatitis B virus, and hepatitis C virus in patients having major surgery. Infect Control Hosp Epidemiol 1995;16:627-32.  Back to cited text no. 8
    
9.
Goetz AM, Ndimbie OK, Wagener MM, Muder RR. Prevalence of hepatitis C infection in health care workers affiliated with a liver transplant center. Transplantation 1995;59:990-4.  Back to cited text no. 9
    
10.
Roome AJ, Halder JL, Thomas AL, Migicovsky B, Roth R, Boraz M. et al. Hepatitis C virus infection among firefighters, emergency medical technicians, and paramedics-selected locations, United States, 1991-2000. MMWR Morb Mortal Wkly Rep 2000;49:660-5.  Back to cited text no. 10
    
11.
Gunn RA, Murray PJ, Ackers ML, Hardison WG, Margolis HS. Screening for chronic hepatitis B and C virus infections in an urban sexually transmitted disease clinic: Rationale for integrating services. Sex Transm Dis 2001;28:166-70.  Back to cited text no. 11
    
12.
Zachary P, Ullmann M, Djeddi S, Meyer N, Wendling MJ, Schvoerer E, et al. Evaluation of three commercially available hepatitis C virus antibody detection assays under the conditions of a clinical virology laboratory. J Clin Virol 2005;34:207-10.  Back to cited text no. 12
    
13.
Recommendations for prevention and control of hepatitis C virus (HCV) infection and HCV-related chronic disease. Centers for Disease Control and Prevention. MMWR Recomm Rep 1998;47:1-39.  Back to cited text no. 13
    
14.
Alter MJ, Kuhnert WL, Finelli L, Centers for Disease Control and Prevention. Guidelines for laboratory testing and result reporting of antibody to hepatitis C virus. Centers for Disease Control and Prevention. MMWR Recomm Rep 2003;52:1-13.  Back to cited text no. 14
    
15.
Parikh R, Mathai A, Parikh S, Chandra Sekhar G, Thomas R. Understanding and using sensitivity, specificity and predictive values. Indian J Ophthalmol 2008;56:45-50.  Back to cited text no. 15
[PUBMED]  Medknow Journal  
16.
Raghuraman S, Subramaniam T, Daniel D, Sridharan G, Abraham P. Occurrence of false positives during testing for antibodies to hepatitis C virus among volunteer blood donors in India. J Clin Microbiol 2003;41:1788-90.  Back to cited text no. 16
    
17.
Guidance for Industry. current good manufacturing practice for blood and blood components: (1). Quarantine and disposition of units from prior collections from donors with repeatedly reactive screening test for antibody to hepatitis C virus (anti-HCV); (2). Supplemental testing, and the notification of consignees and blood recipients of donor test results for anti-HCV;" availability-FDA. Notice. Fed Regist 1998;63:56198-9.  Back to cited text no. 17
    
18.
Centers for Disease Control and Prevention (CDC). Testing for HCV infection: an update of guidance for clinicians and laboratorians. MMWR Morb Mortal Wkly Rep 2013;62:362-5.  Back to cited text no. 18
[PUBMED]    
19.
Chiquete E, Sánchez LV, Maldonado M, Quezada D, Panduro A. Prediction of the hepatitis C viremia using immunoassay data and clinical expertise. Ann Hepatol 2005;4:107-14.  Back to cited text no. 19
    
20.
Bossi V, Galli C. Quantitative signal of anti-HCV by an automated assay predicts viremia in a population at high prevalence of hepatitis C virus infection. J Clin Virol 2004;30:45-9.  Back to cited text no. 20
    
21.
Dufour DR, Talastas M, Fernandez MD, Harris B, Strader DB, Seeff LB. Low-positive anti-hepatitis C virus enzyme immunoassay results: An important predictor of low likelihood of hepatitis C infection. Clin Chem 2003;49:479-86.  Back to cited text no. 21
    
22.
Kim YS, Lee HS, Ahn YO. Factors associated with positive predictability of the anti-HCV ELISA method with confirmatory RT-PCR. J Korean Med Sci 1999;14:629-34.  Back to cited text no. 22
    
23.
Polywka S, Schröter M, Feucht HH, Zöllner B, Laufs R. Relevance of reactivity in commercially available hepatitis C virus antibody assays. J Clin Microbiol 2001;39:1665-8.  Back to cited text no. 23
    
24.
Sookoian S, Castaño G. Evaluation of a third generation anti-HCV assay in predicting viremia in patients with positive HCV antibodies. Ann Hepatol 2002;1:179-82.  Back to cited text no. 24
    
25.
Ren FR, Lv QS, Zhuang H, Li JJ, Gong XY, Gao GJ, et al. Significance of the signal-to-cutoff ratios of anti-hepatitis C virus enzyme immunoassays in screening of Chinese blood donors. Transfusion 2005;45:1816-22.  Back to cited text no. 25
    
26.
Seo YS, Jung ES, Kim JH, Jung YK, Kim JH, An H, et al. Significance of anti-HCV signal-to-cutoff ratio in predicting hepatitis C viremia. Korean J Intern Med 2009;24:302-8.  Back to cited text no. 26
    

Top
Correspondence Address:
Dr. Aseem K Tiwari
Department of Transfusion Medicine, Medanta: The Medicity, Sector - 38, Gurgaon - 122 001, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.154259

Rights and Permissions


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed3223    
    Printed83    
    Emailed0    
    PDF Downloaded45    
    Comments [Add]    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006