Asian Journal of Transfusion Science
Home About Journal Editorial Board Search Current Issue Ahead of print Back Issues Instructions Subscribe Login  Users: 192 Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 10  |  Issue : 1  |  Page : 48-52

Report on errors in pretransfusion testing from a tertiary care center: A step toward transfusion safety


Department of Transfusion Medicine, Government Medical College, Jammu, Jammu and Kashmir, India

Correspondence Address:
Meena Sidhu
F-234, Raipur Satwari, Jammu Cantonment, Jammu and Kashmir
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0973-6247.175402

Rights and Permissions

Introduction: Errors in the process of pretransfusion testing for blood transfusion can occur at any stage from collection of the sample to administration of the blood component. The present study was conducted to analyze the errors that threaten patients' transfusion safety and actual harm/serious adverse events that occurred to the patients due to these errors. Materials and Methods: The prospective study was conducted in the Department Of Transfusion Medicine, Shri Maharaja Gulab Singh Hospital, Government Medical College, Jammu, India from January 2014 to December 2014 for a period of 1 year. Errors were defined as any deviation from established policies and standard operating procedures. A near-miss event was defined as those errors, which did not reach the patient. Location and time of occurrence of the events/errors were also noted. Results: A total of 32,672 requisitions for the transfusion of blood and blood components were received for typing and cross-matching. Out of these, 26,683 products were issued to the various clinical departments. A total of 2,229 errors were detected over a period of 1 year. Near-miss events constituted 53% of the errors and actual harmful events due to errors occurred in 0.26% of the patients. Sample labeling errors were 2.4%, inappropriate request for blood components 2%, and information on requisition forms not matching with that on the sample 1.5% of all the requisitions received were the most frequent errors in clinical services. In transfusion services, the most common event was accepting sample in error with the frequency of 0.5% of all requisitions. ABO incompatible hemolytic reactions were the most frequent harmful event with the frequency of 2.2/10,000 transfusions. Conclusion: Sample labeling, inappropriate request, and sample received in error were the most frequent high-risk errors.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3145    
    Printed81    
    Emailed0    
    PDF Downloaded41    
    Comments [Add]    

Recommend this journal

 

Association Contact us | Sitemap | Advertise | What's New | Feedback | Copyright and Disclaimer

2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006