CASE REPORT Table of Contents   
Year : 2020  |  Volume : 14  |  Issue : 1  |  Page : 79-82
Implication of a positive virtual crossmatch with negative flow crossmatch: A mind-boggler


Department of Transfusion Medicine, Molecular Biology and Transplant Immunology, Indraprastha Apollo Hospital, New Delhi, India

Click here for correspondence address and email

Date of Submission20-Dec-2018
Date of Acceptance16-Oct-2019
Date of Web Publication24-Jul-2020
 

   Abstract 

There are occasions when tests performed before considering a patient for transplant are ambiguous and require further workup. One such condition is the presence of a positive virtual crossmatch (VXm) (anti-human leukocyte antigen [HLA-A]*26: 01 antibody in this case) with a negative complement-dependent cytotoxicity, Luminex, and flow crossmatch. To ascertain the nature of the antibody, the beads used in single-antigen bead assay (SAB) were treated by acid to denature the antigens and retested with the control and test sample. The mean fluorescence intensities (MFIs) from the patient sera with acid-treated beads increased considerably as compared to the regularly untreated SAB indicating additional antigen epitopes become available by the denaturation process. The MFIs of the antibodies from that of the control sera were reduced to half on testing with the acid-treated SAB assay, indicating that HLA antigen HLA-A*26 was susceptible to acid treatment. Therefore, results of VXm should be interpreted with caution.

Keywords: False-positive single antigen bead assay, renal transplant, transplant immunology

How to cite this article:
Chowdhry M, Agrawal S, Thakur Y, Guleria S, Sharma V. Implication of a positive virtual crossmatch with negative flow crossmatch: A mind-boggler. Asian J Transfus Sci 2020;14:79-82

How to cite this URL:
Chowdhry M, Agrawal S, Thakur Y, Guleria S, Sharma V. Implication of a positive virtual crossmatch with negative flow crossmatch: A mind-boggler. Asian J Transfus Sci [serial online] 2020 [cited 2023 Mar 23];14:79-82. Available from: https://www.ajts.org/text.asp?2020/14/1/79/290636





   Introduction Top


With the rise in affordability, accessibility, and availability of good patient and organ donor management protocols, solid organ transplantation is on the rising trend. Opposed to a limited pool of renal organ donors, the number of patients awaiting renal transplant is on the rise owing to a better quality of life.[1] For the optimum utilization of the grafts, a panel of investigations was done using various techniques of donor matching to obtain the best outcome of transplant. These investigations are mainly centered on the detection of preformed antibodies, which can cause hyperacute, acute, and chronic rejection. There are various methods to detect these antibodies, and thereby decrease the occurrence of antibody-mediated rejection. These techniques include Luminex antibody screening, complement-dependent cytotoxicity (CDC) using anti-human globulin (AHG) crossmatch (CDC-AHG Xm), Luminex Crossmatch (LumXm) (Lifecodes, LMD, Immucor), flow crossmatch (FlowXm), and single-antigen bead assay (SAB). SAB assay along with the donor human leukocyte antigen (HLA) typing determines the virtual crossmatch (VXm).[2]

VXm and FlowXm/LumXm correlate well if proper cutoffs are maintained in the SAB assays.[3] However, there are a few occasions when the tests are either ambiguous or require further workup before “ruling in” or “ruling out” the patient for transplant. One such condition is the presence of a positive VXm with a negative CDC, Luminex, and FlowXm which we present here.


   Case Report Top


A 39-year-old female diagnosed with chronic kidney disease-V for 5 years and on hemodialysis for 1 year, was planned for a renal allograft transplant. She is a hypertensive and nondiabetic female with a baseline serum creatinine value of 4.76 mg/dL. She was sent to our department of transfusion medicine and transplant immunology for the pretransplant immunological workup. As a part of routine investigation, the HLA typing was performed for the patient and the prospective donor using sequence-specific primer method (Invitrogen, USA). The mother of the patient was the prospective organ donor. The patient and donor typing to establish relationship are shown in [Table 1].
Table 1: Human leukocyte antigen typing results of patient and donor

Click here to view


As mandated by the Transplant of Human Organs Rules, 1995[4] and the amendments thereof, CDC-AHG was performed which turned out to be negative LumXm, and FlowXm was also negative for the patient. HLA antibody screening (Lifecodes, LMX, Immucor, USA) was performed, which showed high mean fluorescence intensity (MFI) for HLA Class I (MFI 22,659) and II (MFI 19,191).

The cutoff for a positive result is more than or equal to 1000 MFI in our laboratory.

To detect the presence of donor-specific antibody (DSA) against HLA-Class I and II, SAB testing (Lifecodes, LSA Class I and II, Immucor, USA) was performed as a part of the routine workup in transplant patients. There was no DSA detected against HLA Class II antigens. DSA was detected against HLA Class I: A *26:01 (MFI 3826), that is, the VXm was positive in this case.

LumXm was repeated using a fresh sample after heat inactivation at 56° temperature for 30 min and 1:10 dilution to overcome the prozone effect if any. The results of crossmatch were still negative for both HLA Class I and II after heat treatment and/or dilution studies.

SAB was repeated with a fresh sample and with the different lot numbers of the same manufacturer for HLA Class I, but the results did not differ from the previous one.

To summarize, the VXm was positive repeatedly with the negative flow and LumXm. After discussion and determining that proper cutoffs are maintained in all assays, it was hypothesized that these findings were as a result of denatured HLA antigens, and further advanced workup is needed. To test this hypothesis, acid treatment of the beads to denature the antigens was initiated.


   Denaturation of Proteins (Epitopes) on Single-Antigen Beads Top


There have been few case reports in the literature,[5] commenting on the presence of antibodies against cryptic/altered antigens present on the beads of single-antigen assay. To ascertain the nature of the antibody found against anti-HLA-A*26:01 in our case, the beads used in SAB assay were treated by acid to denature the associated antigens. Beads were mixed with ×10 volume of 0.1 M NaAc pH 2.7 (e.g., 10 μl of beads + 100 μl of 0.1 M NaAc) and incubated at room temperature for 30 min. The mixture was then washed two times with basic wash buffer and suspended in phosphate buffer solution.[5]

SAB assay was repeated using these acid-treated beads with the patient's serum. Control sera with known anti-HLA-A*26 specificity were also run using the same acid-treated beads. The MFIs of the antibody from the patient sera with acid-treated beads increased considerably as compared to the regularly untreated SAB. This indicated that additional antigen epitopes became available by the denaturation process. The MFIs of the antibodies from that of the control sera with known anti-HLA-A*26 specificity were reduced to half on testing with the acid-treated SAB assay indicating that the HLA antigen HLA-A*26 on the SAB assay was susceptible to acid treatment [Figure 1] and [Figure 2]. This provided evidence in favor of the presence of antibody against cryptic epitopes present on the beads.[5]
Figure 1: Mean fluorescence intensity values of untreated and acid-treated single antigen bead assay from a control sample

Click here to view
Figure 2: Mean fluorescence intensity values of untreated and acid-treated single antigen bead assay from the test sample

Click here to view


After discussion with the clinician, a consensus was obtained that the patient could be taken up for the transplant, and that these antibodies were actually against the cryptic epitopes, as hypothesized. The patient underwent renal transplant with triple immunosuppression (tacrolimus, prednisolone, and mycophenolate mofetil). Her serum creatinine at discharge on day 7 was 0.8 mg/dL, and the urine output was 4.8 L/day. DJ stent was removed after 4 weeks. Although the follow-up period is too short for evaluation, 6-month posttransplant, the creatinine value continues to be within the normal range (0.76 mg/dL) with no complaints.

The clinical significance of DSA has been enumerated in various studies.[6] One of the biggest advances in the field of histocompatibility testing has been the implementation of VXm based on Luminex-based assays. The SAB assay has enabled the precise analysis of the DSA without the actual “wet crossmatch.” The antigens against which these DSAs are detected are considered unacceptable to proceed for a transplant as such. This augments the need of desensitization in these patients to reduce the DSAs. A negative VXm with no prior history of sensitization such as blood transfusion, pregnancy, or previous transplant is generally safe to proceed for transplant. However, controversies over the implication of a positive VXm in the presence of a negative FlowXm has been elucidated in the literature to a lesser extent. The antibody detected could either by a low-titer antibody not detected in FlowXm but detected in a VXm. Furthermore, the antibody found in a VXm could be against any cryptic antigen/epitope. The implication of such an antibody is unclear. However, it is clear that in the organ allocation criteria, the presence of DSA by the SAB assay would lead to an organ being denied to a patient, which is actually due to the false positivity seen with the denatured antigen. Jacob et al.[5] also support the same theory in their publication, wherein they state that MFI values will increase after acid treatment of beads if additional epitopes are exposed. Ferris et al.[7] and Nishida et al.[8] quote that the human immune system can react to denatured antigens. Alternatively, Morales-Buenrostro et al.[9] have theorized that this may represent the specificity of some “natural” HLA antigen antibodies. However, despite the hypothesis of various origins of these antibodies, the clinical significance still remains unclear.

As described by Otten et al.[10] that a newer generation of beads is available known as iBeads or clean beads, which are devoid of such denatured antigen and can overcome the concerns pertaining to antibodies against denatured antigens. They studied the clinical implication of such antibodies and concluded that only antibodies against intact HLA determine the risk for graft loss, whereas those against denatured epitopes do not. This has further been supported by Visentin et al.[11] In our case, the graft function was maintained until the latest follow-up with normal serum creatinine values supporting the above conclusion.


   Conclusion Top


SAB assays are many a times considered to be superior in antibody detection assays, but should be interpreted in the light of other useful tests such as FlowXm and LumXm which actually detect the actual DSA, more so in case of discordance between the Vxm and Flow/LumXm. In our case, antibodies were directed against denatured form of antigen but not its native form. This antibody did not cause any rejection in the patient (till follow-up). Therefore, we conclude that results of VXm should be interpreted with caution taking into consideration, the clinical history and results of other supplemental tests, as no single test is the ideal one or provides a perfect scenario.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Mohanka R, El Kosi M, Jin JK, Sharma A, Halawa A. Careful interpretation of HLA typing and cross-match tests in kidney transplant. JOJ Uro Nephron 2017;3:555625.  Back to cited text no. 1
    
2.
Konvalinka A, Tinckam K. Utility of HLA antibody testing in kidney transplantation. J Am Soc Nephrol 2015;26:1489-502.  Back to cited text no. 2
    
3.
Tait BD. Detection of HLA antibodies in organ transplant recipients-triumphs and challenges of the solid phase bead assay. Front Immunol 2016;7:570.  Back to cited text no. 3
    
4.
Transplantation of Human Organs and Tissues Rules; 2014. Available from: https://www.notto.gov.in/WriteReadData/Portal/images/THO-Rules-1995-(Original-Rules).pdf. [Last accessed on 2019 Nov 18].  Back to cited text no. 4
    
5.
Jacob EK, De Goey SR, Gandhi MJ. Positive virtual crossmatch with negative flow crossmatch results in two cases. Transpl Immunol 2011;25:77-81.  Back to cited text no. 5
    
6.
Zhang R. Donor-specific antibodies in kidney transplant recipients. CJASN 2018;13:182-92.  Back to cited text no. 6
    
7.
Ferris J, Cooper S, Roessner K, Hochberg M. Antibodies to denatured type II collagen in rheumatoid arthritis: Negative association with igM rheumatoid factor. J Rheumatol 1990;17:880-4.  Back to cited text no. 7
    
8.
Nishida T, Kondo N, Agata H, Fukutomi O, Shinoda S, Suzuki Y, et al. Proliferative responses towards native, heat-denatured and pepsin-treated ovalbumin by peripheral blood mononuclear cells from patients with hen's egg-sensitive atopic dermatitis. Biotherapy 1994;8:33-40.  Back to cited text no. 8
    
9.
Morales-Buenrostro LE, Terasaki PI, Marino-Vázquez LA, Lee JH, El-Awar N, Alberú J, et al. “Natural” human leukocyte antigen antibodies found in nonalloimmunized healthy males. Transplantation 2008;86:1111-5.  Back to cited text no. 9
    
10.
Otten HG, Verhaar MC, Borst HP, van Eck M, van Ginkel WG, Hené RJ, et al. The significance of pretransplant donor-specific antibodies reactive with intact or denatured human leucocyte antigen in kidney transplantation. Clin Exp Immunol 2013;173:536-43.  Back to cited text no. 10
    
11.
Visentin J, Guidicelli G, Moreau JF, Lee JH, Taupin JL. Deciphering allogeneic antibody response against native and denatured HLA epitopes in organ transplantation. Eur J Immunol 2015;45:2111-21.  Back to cited text no. 11
    

Top
Correspondence Address:
Dr. Soma Agrawal
Department of Transfusion Medicine and Transplant Immunology, Indraprastha Apollo Hospital, New Delhi - 110 076
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ajts.AJTS_159_18

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1]

This article has been cited by
1 Principles of Virtual Crossmatch Testing for Kidney Transplantation
Madhu C. Bhaskaran, Sebastiaan Heidt, Thangamani Muthukumar
Kidney International Reports. 2022;
[Pubmed] | [DOI]



 

Top
 
  Search

  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Case Report
    Denaturation of ...
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1854    
    Printed68    
    Emailed0    
    PDF Downloaded107    
    Comments [Add]    
    Cited by others 1    

Recommend this journal

Association Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice


© 2006 - Asian Journal of Transfusion Science | Published by Wolters Kluwer - Medknow
Online since 10th November, 2006